Breaking Capacity: | Low Voltage Circuit Breakers |
---|---|
Operation: | Manual Type |
Speed: | Normal Type Circuit Breaker |
Still deciding? Get samples of US$ 0/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
M63MF5 AC Miniature Circuit Breaker MCB 2P 3P 4P, Overload protection, Short circuit protection , remote opening and closing, temperature detection, overvoltage and undervoltage protection (optional), phase loss protection (optional), power outage and trip (optional), line sequence protection (optional), RS485&4G data transmission
Product Name | M63MF5 2P | M63MF5 3P | M63MF5 4P | |
Standard | GB/T 10963.1 IEC60898-1 | |||
Product certification | CCC CE CB | |||
size (mm) | 80.2 | 106.8 | 124.4 | |
Number of poles | 4.5 modules | 6 modules | 7 modules | |
Functions | Overload protection, Short circuit protection, remote opening and closing,temperature detection. overvoltage and undervoltage protection (optional), power outage and trip (optional), RS485&4G data transmission | Overload protection, Short circuit protection , remote opening and closing, temperature detection, overvoltage and undervoltage protection (optional), phase loss protection (optional), power outage and trip (optional), line sequence protection (optional), RS485&4G data transmission | ||
Wiring method | Up in and down out (with Wiring markings) | |||
Rated current(A) | 1A, 2A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A | |||
Rated voltage(V) Un | 230 | 400 | ||
Rated insulation voltage(V) Ui | 500 | |||
Overvoltage (V) Uve (optional) | 275_+5v | 460_+5v | ||
Undervoltage(V) Uoe (optional) | 165_+5v | 290_+5v | ||
power outage and trip | Optional configuration | |||
Phase loss protection | / | Optional configuration | ||
Line sequence protection | / | Optional configuration | ||
Rated operating frequency (Hz) | 50/60 | |||
Rated impulse withstand voltage (V) Uimp | 4000 | |||
Rated short-circuit capacity lcn | 6000 | |||
Rated short-circuit breaking capacity lcs | 6000 | |||
Transmission type | TRS485&4G | |||
Overvoltage category | Second | |||
pollution capacity | 2 | |||
Instantaneous tripping characteristics | B (3ln-7ln) | Ye | ||
C (5ln-10ln) | Ye | |||
D (10ln-15ln) | Ye | |||
Electric shock protection level | Second | |||
Remote opening and closing service life | 15000 | 10000 | ||
Mechanical characteristics mechanical life | 20000 | |||
Protection level | Circuit breaker | IP20 | ||
Installed in the distribution box | IP40 | |||
Maximum wiring capacity (2) | 50 | |||
Terminal ultimate torque (Nm) | 5 |