Breaking Capacity: | Low Voltage Circuit Breakers |
---|---|
Operation: | Manual Type |
Speed: | Normal Type Circuit Breaker |
Still deciding? Get samples of US$ 0/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
M63LS4 Intelligent ELCB 1P+N, 3P+N, 3P, Parallel assembly, overload protection, Short circuit protection, leakage protection, energy metering, temperperature,detection, overvoltage and undervoltage protection(optional), phase lossprotection(optional), power outage and tripping (optional), line sequence protection(optional) gateway transmission, DC power supply
Product Name | M63LS4 1P+N | M63LS4 3P+N | M63LS4 3P | |
Standard | GB/T 16917.1 IEC61009-1 | |||
Product certification | CCC CE CB | |||
size (mm) | 62.2 | 106.4 | 106.4 | |
Number of poles | 3.5 modules | 6 modules | 6 modules | |
Functions | Parallel assembly, overload protection, Short circuit protection,leakage protection, energy metering, temperperature,detection, overvoltage and undervoltage protection(optional), power outage and trip (optional),gateway transmission, DC power supply | Parallel assembly, overload protection, Short circuit protection, leakage protection, energy metering, temperperature,detection, overvoltage and undervoltage protection(optional), phase lossprotection(optional), power outage and tripping (optional), line sequence protection(optional) gateway transmission, DC power supply | ||
Wiring method | Up in and down out (with Wiring markings),zero line markings | Up in and down out (with Wiring markings) | ||
Rated current(A) | 1A, 2A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A | |||
Rated leakage current(mA) | 10, 30, 100, 300, 500 | |||
Leakage release type | AC type A type | |||
Rated voltage(V) Un | 230 | 400 | ||
Rated insulation voltage(V) Ui | 500 | |||
Overvoltage (V) Uve (optional) | 275±5v | 460±5v | ||
Undervoltage(V) Uoe (optional) | 165±5v | 290±5v | ||
power outage and trip | Optional configuration | |||
Phase loss protection | / | Optional configuration | ||
Line sequence protection | / | Optional configuration | ||
Rated operating frequency (Hz) | 50/60 | |||
Rated impulse withstand voltage (V) Uimp | 4000 | |||
Rated short-circuit capacity lcn | 6000 | |||
Rated short-circuit breaking capacity lcs | 6000 | |||
Measurement accuracyy | ±0.5% | |||
Connection method | parallel assembly, track PCBA connection | |||
Overvoltage category | Second | |||
pollution capacity | 2 | |||
Instantaneous tripping characteristics | B (3ln-7ln) | B curve (3ln-7ln) | ||
C (5ln-10ln) | C curve (5ln-10ln) | |||
D (10ln-15ln) | D curve (10ln-15ln) | |||
Electric shock protection level | Second | |||
Mechanical characteristics mechanical life | 20000 | |||
Protection level | Circuit breaker | IP20 | ||
Installed in the distribution box | IP40 | |||
Maximum wiring capacity (2) | 50 | |||
Terminal ultimate torque (Nm) | 5 |