• Outdoor High Voltage Metal Oxide Surge Arrester
  • Outdoor High Voltage Metal Oxide Surge Arrester
  • Outdoor High Voltage Metal Oxide Surge Arrester
  • Outdoor High Voltage Metal Oxide Surge Arrester
  • Outdoor High Voltage Metal Oxide Surge Arrester
  • Outdoor High Voltage Metal Oxide Surge Arrester

Outdoor High Voltage Metal Oxide Surge Arrester

Installation: Parallel Arrester
Application: AC/DC System
Size: Large
Operation Voltage: High Voltage
Shape: Gyro Type
Certification: CCC
Samples:
US$ 600/Piece 1 Piece(Min.Order)
| Request Sample
Gold Member Since 2024

Suppliers with verified business licenses

Gansu, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (11)
  • Overview
  • General Introduction
  • Product Description
  • Detailed Photos
Overview

Basic Info.

Model NO.
YW
Standard
IEC60099-4
Rated Voltage
35kv to 1000kv
Outdoor or Indoor
Outdoor
System Voltage
35kv to 1000kv
Transport Package
Non-Fumigation Wooden Box
Specification
Please refer to the attachment
Trademark
XD
Origin
China
HS Code
8535400000
Production Capacity
50000

Product Description

Metal Oxide Surge Arrester
General Introduction

General:
35kV~1000kV
 porcelain housed Metal Oxide Surge Arrester, 6kV~750kV polymeric Metal  Oxide Surge Arrester, 72.5kV~800kV GIS  Metal Oxide Surge Arrester, Metal Oxide Surge Arrester for specific applications and conditions such as Metal Oxide Surge Arrester for high altitude or high polluted regions, 3-phases combined Metal Oxide Surge arrester for  arresting  inter-phase  and  phase-to-ground   overvotages, 6kV~35kV harmonic suppressor, non-linear resistors for  electric locomotives, monitors and discharge counters for Metal Oxide Surge Arrester etc.
DC and AC MOA and other accessories manufactured by XDSA in according with IEC60099-4 and GB11032
A) 35kV~1000kV  porcelain  housed  gapless Metal Oxide Surge Arrester
B) 72.5kV~800kV GIS gapless Metal Oxide Surge Arrester
C) 6kV~750kV  polymeric  gapless  Metal Oxide Surge Arrester
D) 35kV~500kV polymeric line type Metal Oxide Surge Arrester with serious gaps
E) Complete set of gapless Metal Oxide Surge Arrester for DC transmission project
F) Gapless Metal Oxide Surge Arrester for electrified railway
G) Discharge counters and monitors for Metal Oxide Surge Arrester

Features:
1. Superior protective performance
possesses superior nonlinear volt-ampere characteristics and high discharge capacity, making a great protective margin of discharge voltages at steep-front, lightning and switching current surges, resulting to a wellovervoltage restricting, effect.
2. 
Reliable sealing performance
The reliable sealing during whole MOA service life is ensured by application of weatherproof O-shaped rubber ring, specific  sealing design,patented pattern of mini-positive pressure and   high-sensitive helium mass spectrometric detecting technology.
3. Satisfactory ageing performance
characterized by superior ageing-proof performance, high discharge capacity, great overvoltage absorption capability, stable  electrical characteristics, high electric stress ratio bearing ability, resulting to reliable service performance.
4. 
Safe pressure relief capability
Pressure relief device, specially designed for power utilities, has reliable pressure relief capability which ensures safe relief inner pressure of Metal Oxide Surge Arrester in event of  failure to  prevent any failure spread.
5. Uninterrupted innovation in Hi-tech product development
Unceasing aimed at worldwide trend of Metal Oxide Surge Arrester development, constantly devotes herself to  development of  Hi-tech Metal Oxide Surge Arrester  of worldwide advanced level, making a first class Metal Oxide Surge Arrester.

Usys: Nominal system voltage
Ucov: Continous operating voltage
Ur: Rated voltage of Metal Oxide Surge Arrester
Ures: Residual voltage of Metal Oxide Surge Arrester
U1mA: 1mA DC reference voltage
Uref: AC refererence voltage
L2ms: Rectangular 2ms withstand discharge current.
Ums: Impu1se sparkover voltage
Lspec: Specific Creepage distance

Product Description

1. Technical parameters of 35KV~1000KV station type gapless Metal Oxide Surge Arrester.

Usys   KVr.m.s Model Ur    KVr.m.s Ucov     KVr.m.s Ures    KVp     U1mA      ≥kV Uref         ≥KVr.m.s I2ms       A Lspec   mm/kV         H          mm  D    mm  Weight   kg Units Number
1/10 8/20 30/60
35 Y5W-51/134W 51 40.8 154 134 114 73 51 400 31 1005 250 78 1
35     Neutral Y1.5W-30/80W 30 24 / 80 75 44 30 400
66 Y5W-84/221W 84 67.2 254 221 188 121 84 600,  800 25/31 1704/1835 310 176/202 1
Y5W-90/235W 90 72.5 270 235 201 130 90 600,  800
Y10W-90/235 90 72.5 264 235 201 130 90 600,  800
110 Y10W-96/250W 96 75 280 250 213 140 96 600,  800
Y10W-100/260W 100 78 291 260 221 145 100 600,  800
Y10W-102/266W 102 79.6 297 266 226 148 102 600,  800
Y10W-108/281W 108 84 315 281 239 157 108 600,  800
110 Neutral Y1.5W-60/144W 60 48 / 144 135 85 60 400 25/31 1005 250 78/82 1
Y1.5W-72/186W 72 58 / 186 174 103 72 400
220 Y10W-192/500W 192 150 560 500 426 280 192 600,  800 25/31 3138/3400 850 400/412 2
Y10W-200/520W 200 156 582 520 442 290 200 600,  800
Y10W-204/532 204 159 594 532 452 296 204 600,  800
Y10W-216/562W 216 168.5 630 562 478 314 216 600,  800
220  Neutral Y1.5W-144/320W 144 116 / 320 299 205 144 400,  600 25 1835 310 202 1
330 Y10W-228/698W 288 219 782 698 593 408 288 1200 25/31 3732/3992 1120 580/ 2
  Y10W-312/760W 312 237 847 760 643 442 312 1200          
330 Neutral W1.5W-207/440W 207 166 / 440 410 292 207 600 31 3400 850 412 2
500 Y20W-420/1046W 420 318 1170 1046 858 565 420 2000, 2500 25/31 5856/6111 1500 1565/1650 3
Y20W-444/1106W 444 324 1238 1106 907 597 444 2000, 2500
Y20W-468/1166W 468 330 1306 1166 956 630 468 2000, 2500
500 Neutral Y1.5W-102/260W 102 155 / 260 243 82 102 600 31 1835 310 202 1
Y1.5W-96/260W 96 137 / 260 243 77 96 600
750 Y20W-600/1380W 600 462 1518 1380 1142 810 600 2500 25/31 8024/8884 2500 2353/2553 4
Y20W-648/1491W 648 498 1639 1491 1226 875 648 2500
1000 Y20W-828/1620W 828 638 1782 1620 1460 1130(4mA) 828 8800 25 11600 3800 6300 5

2. Technical parameters of 66~800KV metal clad gapless Metal Oxide Surge Arrester.

Usys   kVr.m.s Model Ur      KVr.m.s. Ucov     KVr.m.s. Ures    ≤kVp    U1mA   ≥kV Uref         ≥KVr.m.s. I2ms       A      H      mm    D     mm Weight     kg Configuration
1/10 8/20 30/60
66 Y5WF-84/221 84 67.2 254 221 188 121 84 600,  800  1280   1600 350      218      256 Top outlet    Side outlet
Y10WF-90/235 90 72.5 264 235 201 130 90 600,  800
Y5WF-84/221 84 67.2 254 221 188 121 84 600,  800 1385  1830 618    656    742
Y10WF-90/235 90 72.5 264 235 201 130 90 600,  800
110 Y10WF-96/250 96 75.0  280 250 213 140 96 600,  800 1280 1600 350      230       275 Top outlet    Side outlet
Y10WF-100/260 100 78.0  291 260 221 145 100 600,  800
Y10WF-102/266 102 79.6 297 266 226 148 102 600,  800
Y10WF-108/281 108 84.2 315 281 239 157 108 600,  800
Y10WF-96/250 96 75 280 250 213 140 96 600,  800 1385 1830 618       686       772
Y10WF-100/260 100 78 291 260 221 145 100 600,  800
Y10WF-102/266 102 79.6 297 266 226 148 102 600,  800
Y10WF-108/281 108 84.2 315 281 239 157 108 600,  800
220 Y10WF-200/520 200 156 582 520 442 290 200 800 1665 460 312 Top outlet    Side outlet
Y10WF-204/532 204 159 954 532 452 296 204 800 1900 460 361
Y10WF-216/562 216 168.5 630 562 478 314 216 800 1550 718  
330 Y10WF-288/698 288 219 782 698 593 408 288 1200 1900 812 975 Top outlet  
Y10WF-300/727 300 228 814 727 618 425 300 1200
Y10WF-324/789 324 246 880 789 668 459 324 1200
500 Y20WF-420/1006 420 318 1096 1006 832 586 420 2000, 2500 2540* 2505* 987   1106     692      1072 Top outlet    Side outlet
Y20WF-444/1063 444 324 1159 1063 882 620 444 2000, 2500
Y20WF-468/1120 468 330 1222 1120 926 653 468 2000, 2500
750 Y20WF-600/1380 600 462 1518 1380 1142 810 600 2500 3350* 2860* 1406 1406     2300     2200  Side outlet
Y20WF-648/1149 648 498 1639 1491 1226 875 648 2500

3. Technical parameters of 6KV~500KV station and distribution type polymeric gapless Metal Oxide Surge Arrester.

Usys   KVr.m.s. Model Ur    KVr.m.s. Ucov     KVr.m.s. Ures    ≤KVp U1mA     ≥KV Uref  KVr.m.s.        I2ms     A Lspec   mm/KV    H      mm  D     mm Weight      kg Units Number
1/10 8/20 30/60
6 YH5WS-10/30W 10 8 34.6 30 25.6 15 10 100 31 257 100 3 1
YH5WZ-10/27W 10 8 31 27 23 14.4 10 150
10 YH5WS-17/50W 17 13.6 57.5 50 42.5 25 17 100 31 257 100 2 1
YH5WZ-17/45W 17 13.6 51.8 45 38.3 24 17 150
35 YH5W-51/134W 51 40.8 154 134 114 73 51 400 31 682 140 15 1
66 YH5W-84/221W 84 67.2 254 221 188 121 84 600,  800 31 1264 220 62 1
YH10W-90/235W 90 72.5 264 235 201 130 90 600,  800          
110 YH10W-100/260W 100 78 291 260 221 145 100 600,  800 31 1264 220 62 1
YH10W-102/266W 102 79.6 297 266 226 148 102 600,  800
YH10W-108/281W 108 84 315 281 239 157 108 600,  800
110 Neutral YH1.5W-60/144W 60 48   144 135 85 60 400 31 949 184 32 1
YH1.5W-72/186W 72 58   186 174 103 72 400
220 YH10W-200/520W 200 156 582 520 442 290 200 600,  800 31 2335 850 124 2
YH10W-204/532W 204 159 594 532 452 296 204 600,  800
YH10W-216/562W 216 168.5 630 562 478 314 216 600,  800
220 Neutral YH1.5W-144/320W 144 116 / 320 299 205 144 400 31 1856 184 65 2
330 YH10W-288/698W 288 219 782 698 593 408 288 1200 31 3530 362 450 2
YH10W-300/727W 300 228 814 727 618 425 300 1200
YH10W-306/742W 306 233 831 742 630 433 306 1200
YH10W-312/760W 312 237 847 760 643 442 312 1200
YH10W-324/789W 324 246 880 789 668 459 324 1200
330 Neutral YH1.5W-207/440W 207 166 / 440 410 292 207 600 31 2335 220 124 2
500 YH20W-420/1046W 420 318 1170 1046 858 565 420 2000 31 5000 362 662 3
YH20W-444/1106W 444 324 1238 1106 907 597 444 2000
YH20W-468/1166W 468 330 1306 1166 956 630 468 2000
 500 Neutral YH1.5W-102/260W 102 82 / 260 243 155 102 600 31 1264 220 62 1
YH1.5W-96/260W 96 77 / 260 243 137 96 600

4. Technical parameters of line protection polymeric gapless Metal Oxide Surge Arrester.

Usys   KVr.m.s. Model Ur    KVr.m.s. Ucov     KVr.m.s. Ures    ≤KVp U1mA     ≥KV Uref         ≥KVr.m.s.          I2ms       A Lspec   mm/KV  H    mm D     mm Weight kg Units Number
1/10 8/20 30/60
35 YH5WX-51/134W 51 40.8 154 134 114 73 51 600,  800 31 661 140 13 1
66 YH10WX-96/250W 96 75 288 250 213 140 96 600,  800 31 1256 210 48 1
110 YH10WX-108/281W 108 84 315 281 239 157 108 600,  800 31 1256 210 48 1
  YH10WX-114/297W 114 89 341 297 252 165 114 600,  800          
220 YH10WX-216/562W 216 168.5 630 562 478 314 216 600,  800 31 2472 850 99 2
330 YH10WX-312/760 312 237 847 760 643 442 312 600,  800 31 3630 1200 256 3
YH10WX-324/789 324 246 880 789 668 459 324 1200
550 YH20WX-444/1106W 444 324 1238 1106 907 597 444 1200 31 5098 2000 405 3
YH20WX-468/1166W 468 330 1306 1166 956 630 468 1800
750 YH20WX-648/1491W 648 498 1639 1491 1226 875 648 20001800 31 7855 2500 800 5

5. Technical parameters of 110~500KV polymeric gapped Metal Oxide Surge Arrester.

Usys   KVr.m.s Model Metal Oxide Surge Arrester Body Metal Oxide Surge Arrester.    H       mm  D          mm  Weight  kg Units Number
Ur  KVr.m.s. Ur    KVr.m.s. U1mA     ≥KV Uref        ≥KVr.m.s.  I2ms       A  ≥KVr.m.s.  Uimpspv ≥KVr.m.s.  Gap space  mm
1/10 8/20
35 YH5CX-42/120 42 132 120 60 42 250 82 240 220±20 661 140 20 1
110 YH10CX-84/220 84 252 220 123 84 400 185 525 550±50 1100/2100 168 39/46 1
YH10CX-90/260 90 292 260 130 90 400
YH10CX-96/280 96 314 280 140 96 400
YH10CX-108/265 108 358 320 160 108 400
220 YH10CX-180/520 168 584 520 260 168 600 370 900 900±50 2100/3200 168 72/85 2
YH10CX-192/560 192 628 560 280 192 600
YH10CX-216/640 216 716 640 320 216 600
500 YH20CX-396/1050 396 1171 1050 561 396 1200 567 1760 1650±150 3738/6130 225 270/292 3
YH20CX-396/1050 396 1171 1050 561 396 1200

6.  Technical parameters of gapless Metal Oxide Surge Arrester for electrified railway protection

Usys   KVr.m.s. Model Ur  KVr.m.s. Ucov     KVr.m.s. Ures    ≤KVp U1mA     ≥KV Uref        ≥KVr.m.s. I2ms       A Lspec   mm/KV H           mm D           mm Weight       kg Units Number
1/10 8/20 30/60
27.5 YSWT-42/120W 42 34 138 120 98 65 42 400 31 1005 250 78 1
Y10WT-42/120W 42 34 157 140 119 65 42 400
YH5WT-42/120W 42 34 138 120 98 65 42 400 682 140 15 1
55 Y5WT-84/240W 84 68 276 240 196 130 84 400,  600 31 1835 310 202 1
Y10WT-84/260W 84 68 291 260 221 130 84 400,  600
YH5WT-84/240 84 68 276 240 196 130 84 400,  600 31 1264 220 62 1
YH10WT-84/240W 84 68 276 240 196 130 84 400,  600
110 Y5WT-100/260W 100 78 299 260 221 145 100 600,  800 31 1835 310 202 1
Y10WT-100/275W 100 73 316 275 234 145 100 600,  800
YH5WT-100/260W 100 78 299 260 221 145 100 600,  800 1264 220 62 1
YH10WT-100/275W 100 73 316 275 234 145 100 600,  800

7.  Technical parameters of polymeric gapless Metal Oxide Surge Arrester for electric locomotives

Usys   KVr.m.s Model Ur  KVr.m.s, Ucov     KVr.m.s. Ures    ≤kVp U1mA     ≥KV Uref        ≥KVr.m.s. I2ms       A Lspec   mm/KV  H      mm D      mm Weight KG Units Number
1/10 8/20 30/60
27.5 YH10WT-42/105 42 31.5 118 105 89 58 40 400 31 562 150 17 1

8. Technical parameters of Metal Oxide Surge Arrester for protecting electric rotating machines.

Application Model Ur  KVr.m.s. Ucov     KVr.m.s. Ures    ≤KVp U1mA     ≥KV Uref        ≥KVr.m.s. I2ms       A
1/10 8/20 30/60
Generator YH5W-4/9.5 4 3.2 10.7 9.5 7.6 5.7 3.8 400
YH5W-8/18.7 8 6.3 21 18.7 15 11.2 7.7 400
YH5W-13.5/31 13.5 10.5 34.7 31 25 18.6 13 400
YH5W-17.5/40 17.5 13.8 44.8 40 32 24.4 17 400
YH5W-20/45 20 15.8 50.4 45 36 28 19.5 400
YH5W-23/51 23 18.0  57.2 51 40.8 31.9 21.9 400
YH5W-25/56.2 25 20.0  62.9 56.2 45 35.4 24.3 400
Motor YH2.5W-4/9.5 4 3.2 10.7 9.5 7.6 5.7 3.8 400
YH2.5W-8/18.7 8 6.3 21 18.7 15 11.2 7.7 400
YH2.5W-13.5/31 13.5 10.5 34.7 31 25 18.6 13 400
Neutral Of Electric Machine YH1.5W-2.4/6 2.4 1.9 _ 6 5 3.4 2.4 400
YH1.5W-4.8/12 4.8 3.8 _ 12 10 6.8 4.8 400
YH1.5W-8/19 8 6.4 _ 19 15.9 11.4 8 400
YH1.5W-10.5/23 10.5 8.4 _ 23 19.2 14.9 10.5 400
YH1.5W-12/26 12 9.6 _ 26 21.6 17 12 400
YH1.5W-13.7/29.2 13.7 11 _ 29.2 24.3 19.5 13.7 400
YH1.5W-15.2/31.7 15.2 12.2 _ 31.7 26.4 21.6 15.2 400

9.  Technical parameters of gapless Metal Oxide Surge Arrester for shunt compensation capacitor bank

Usys   KVr.m.s. Model Ur  KVc.m.s. Ucov     KVr.m.s. Ures    ≤KVp U1mA     ≥KV Uref        ≥KVr.m.s. I2ms       A Lspec   mm/KV H    mm D    mm Weight kg Units Number
8/20 30/60
6 YH10WR-10/27W 10 8 27 21 14.4 10 400 31 297 108 3.4 1
10 YH10WR-12/32.4W 12 9.6 32.4 25.2 17.4 12 400
YH10WR-15/40.5W 15 12 40.5 31.5 21.8 15 400
YH10WR-17/46W 17 13.6 46 35 24 17 400
35 YH5WR-51/134 51 40.8 134 105 73 51 400-2000 30 682 140 15 1
YH5WR-51/134 51 40.8 134 105 73 51 1005 250 78 1
Y10WR-54/134W 54 43.2 134 105 75 51 1175 290 140 1
Y10WR-52.7/134W 52.7 42.2 134 105 73.5 51 1192 345 205 1
110 Y10WR-84/221W 84 67.2 221 176 121 84 600-2000 25/31 1704-2032 310-351 176-202 1
Y10WR-90/236W 90 72.5 236 190 130 90

10. Technical parameters of complete Metal Oxide Surge Arrester for static Var compensation device (SVC)

Model Usys
KV (r.m.s.)
Ucov
KV (r.m.s.)
U1mA     ≥KV Uref
KV (r.m.s.)
I2ms       A Ures       ≤KVp    8/20
Y0.5WR-45/106 35 41.26 76.4 45 600 106
Y0.5WR-45/110 35 38.8 76.3 45 1200 110
Y0.5WR-42/98.7 35 34.8 69.6 42 600 98.7
Y0.5WR-36/81.6 35 28.36 56.6 36 600 81.6
Y0.5WR-42/92 35 23 60 42 600 92
Y0.5WR-24/56.2 35 23 37.8 24 600 56.2

11. Technical parameters of 3-phases polymeric combinative Metal Oxide Surge Arrester

Usys
KV (r.m.s.)
Model Connection mode Ucov
KV
Ures    ≤KVp U1mA
≥KV
I2ms
A
1/4 8/20 30/60
10 H5WZ-17/45×2 Phase-Phase 13.6 51.8 45 38.3 25 200
Phase-Ground 13.6 51.8 45 38.3 24 200
35 H5WZ-51/134×51/150 Phase-Phase 40.8 170 150 134 84 400
Phase-Ground 40.8 154 134 114 73 400

12. The cable protector is designated for protecting insulating sheath from damage of overvoltages and automatic counting its operation number at overvoltages. The technical parameters and outline dimensions of BYLJS type cable protector.

Model Usys
KV (r.m.s)
Uwith AC/dur
KV (r.m.s./s)
Ures  at 10kA
≤KVp
U1mA
≥KV
Weight
KG
H
mm
BYLJS-35 35 5/4 13 5.5 6.2 365
BYLJS-110(1) 110 5/4 15 5.5 6.2 365
BYLJS-110(2) 110 10/4 30 11 6.5 365
BYLJS-220 220 6/3 35 37 6.3 365
BYLJS-500 500 5/4 18(16kA) 5.5 6.2 365

13. Harmonic repressor is a our patented device (patent number 85200817.1) to be used in system with non-grounded neutral, being designed for damping ferro-resonance caused by voltage interreaction and ating overcurrent passing through HV winding of  instrument transformer at one-phase earthing or arcing earthing thus protecting potential transformer from burst. The main technical parresrameters (6KV-24KV):

Model Nonlinear Coef Ures.d.c U1min
KV (r.m.s.)
Ua.c 250mA 10min Ia.c 20mA 2h  Height
mm
Weight 
kg
Diameter
mm
RXQ1-6-10 0.5-0.6 1.45-1.7(15mA) 9 pass pass 430 8.5 125
RXQ1-35 0.22-0.277 ≥2.8(50mA) 5 pass(350mA) pass(350mA) 322 6.5 125

14. JCQ3 Monitor is a device to be connected seriously beneath 35kV~750kV Metal Oxide Surge Arrester for monitoring leakage   current and counting discharge number. The technical parameters:

Usys
KV 
Model In   8/20
KAp
Id   8/20
Ap
I2ms    Ap High cur. withstand
4/10  kAp
Ures
kVp
Basic scale of current
mA (r.m.s.)
Weight
KG
6-220 JCQ3A-10/600 10 50 800 100 1.5 0-2 3
330 JCQ3A-10/150 1500 0-5
550 JCQ3A-20/200 20 2000
750 JCQ3A-20/250 2500 0-6 3.5
Detailed Photos
Outdoor High Voltage Metal Oxide Surge Arrester
Outdoor High Voltage Metal Oxide Surge Arrester
Outdoor High Voltage Metal Oxide Surge Arrester
Outdoor High Voltage Metal Oxide Surge Arrester
Outdoor High Voltage Metal Oxide Surge Arrester
Outdoor High Voltage Metal Oxide Surge Arrester

 

















                

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now