M63LC Automatic Closing ELCB RCCB Circuit breaker  power failure  trip overvoltage  undervoltage

Product Details
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Speed: Normal Type Circuit Breaker
Still deciding? Get samples of US$ 0/Piece
Request Sample
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (11)
  • M63LC Automatic Closing ELCB RCCB Circuit breaker  power failure  trip overvoltage  undervoltage
  • M63LC Automatic Closing ELCB RCCB Circuit breaker  power failure  trip overvoltage  undervoltage
  • M63LC Automatic Closing ELCB RCCB Circuit breaker  power failure  trip overvoltage  undervoltage
  • M63LC Automatic Closing ELCB RCCB Circuit breaker  power failure  trip overvoltage  undervoltage
  • M63LC Automatic Closing ELCB RCCB Circuit breaker  power failure  trip overvoltage  undervoltage
  • M63LC Automatic Closing ELCB RCCB Circuit breaker  power failure  trip overvoltage  undervoltage
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
Overview

Basic Info.

Model NO.
M63LC
Arc-extinguishing Medium
Air
Installation
DIN RAIL
Structure
MCB
Poles Number
1P+N, 3P, 3P+N
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
CE, CB, CCC
Standard
IEC60898-1
Protection Function
Short Circuit Protection, Overload Protection
Rated insulation voltage
500V
Rated operating frequency
50/60Hz
Rated ultimate breaking capacity
6000A
Rated service breaking capacity
6000A
Rated Leakage Current
10mA, 30mA, 100mA, 300mA, 500mA
Transport Package
Carton
Specification
1A 2A 4A 6A 10A 16A 20A 25A 32A 40A 50A 63A
Trademark
JMT
Origin
China
HS Code
8536200000
Production Capacity
8000000

Product Description

Product Description

M63LC Intelligent ELCB RCCB Circuit breaker Overload protection, Short circuit protection,leakage protection, power outage and trip, automatic closing upon power on,  overvoltage and undervoltage protection (optional), phase loss protection (optional), and line sequence protection (optional)

Product Parameters
Product Name M63LC  1P+N M63LC  3P M63LC  3P+N
Standard GB/T 116917.1   IEC61009-1
Product certification CCC  CE  CB
size (mm) 71.2 115.4 124.4
Number of poles 4 modules 6.5 modules 7 modules
Functions Overload protection, Short circuit protection, leakage protection, power outage and trip , automatic closing upon power on, overvoltage and undervoltage protection (optional) Overload protection, Short circuit protection,leakage protection, power outage and trip, automatic closing upon power on,  overvoltage and undervoltage protection (optional), phase loss protection (optional), and line sequence protection (optional)
Rated current(A) 1A, 2A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
Rated leakage current(mA) 10,   30,   100,   300,   500
Leakage release type AC  type  A type
Rated voltage(V) Un 230 400
Rated insulation voltage(V) Ui 500
Overvoltage (V)  Uve (optional) 275_+5v 460_+5v
Undervoltage(V)  Uoe (optional) 165_+5v 290_+5v
power outage and trip Optional  configuration
Phase loss protection / Optional  configuration
Line sequence protection / Optional  configuration
Rated operating frequency (Hz) 50/60
Rated impulse withstand voltage (V) Uimp 4000
Rated short-circuit capacity lcn 6000
Rated short-circuit breaking capacity lcs 6000
Overvoltage category Second
pollution capacity 2
Instantaneous tripping characteristics B (3ln-7ln) Ye
C (5ln-10ln) Ye
D (10ln-15ln) Ye
Electric shock protection level Second
Mechanical characteristics mechanical life 20000
Protection level Circuit breaker IP20
Installed in the distribution box IP40
Maximum wiring capacity (2) 50
 Terminal ultimate torque (Nm)  5
Detailed Photos
M63LC Automatic Closing ELCB RCCB Circuit breaker power failure trip overvoltage undervoltage
M63LC Automatic Closing ELCB RCCB Circuit breaker power failure trip overvoltage undervoltage
M63LC Automatic Closing ELCB RCCB Circuit breaker power failure trip overvoltage undervoltage
M63LC Automatic Closing ELCB RCCB Circuit breaker power failure trip overvoltage undervoltage
M63LC Automatic Closing ELCB RCCB Circuit breaker power failure trip overvoltage undervoltage
M63LC Automatic Closing ELCB RCCB Circuit breaker power failure trip overvoltage undervoltage
M63LC Automatic Closing ELCB RCCB Circuit breaker power failure trip overvoltage undervoltage
M63LC Automatic Closing ELCB RCCB Circuit breaker power failure trip overvoltage undervoltage
M63LC Automatic Closing ELCB RCCB Circuit breaker power failure trip overvoltage undervoltage
M63LC Automatic Closing ELCB RCCB Circuit breaker power failure trip overvoltage undervoltage

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now