• High Voltage Porcelain Type SF6 Gas Circuit Breaker LW9-40.5 LW9-72.5 LW9A-72.5
  • High Voltage Porcelain Type SF6 Gas Circuit Breaker LW9-40.5 LW9-72.5 LW9A-72.5
  • High Voltage Porcelain Type SF6 Gas Circuit Breaker LW9-40.5 LW9-72.5 LW9A-72.5
  • High Voltage Porcelain Type SF6 Gas Circuit Breaker LW9-40.5 LW9-72.5 LW9A-72.5
  • High Voltage Porcelain Type SF6 Gas Circuit Breaker LW9-40.5 LW9-72.5 LW9A-72.5
  • High Voltage Porcelain Type SF6 Gas Circuit Breaker LW9-40.5 LW9-72.5 LW9A-72.5

High Voltage Porcelain Type SF6 Gas Circuit Breaker LW9-40.5 LW9-72.5 LW9A-72.5

Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: SF6
Installation: Vertical
Structure: Porcelain
Gold Member Since 2024

Suppliers with verified business licenses

Gansu, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (11)
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
Overview

Basic Info.

Model NO.
LW9
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
Certification
CE, CCC
Phase
3
Outdoor or Indoor
Outdoor
Rated Voltage
40.5kv to 550kv
Rated Current
2000A, 3150A, 4000A, 5000A
Transport Package
Non-Fumigation Wooden Box
Specification
Please refer to the attachment
Trademark
XD
Origin
China
HS Code
8535291000
Production Capacity
5000

Product Description

Outdoor High Voltage Porcelain Type SF6 Gas Power Circuit Breaker for Substation.
Product Description
1.General
H.V.A.C.porcelain type SF6 gas circuit breakers, with voltage from 40.5-550kV and rated current up to 4000A, manufac-tured by our company, are provided with three kinds of operating mechanism, pneumatic, spring and hydraulic type. Motor is used in spring mechanism to charge closing spring and charge opening spring at closing. Disk spring is used in hydraulic mechanism to be charged in stead of traditional compressed nitrogen gas for charge, and hydraulic driv ing is used at both opening and closing. Compressed air is used in pneumatic mechanism as driven force for open while spring is used for close. The three kinds of operating mechanisms have their own features and are used in circuit breakers of different voltage class respectively.Due to the unit structure in circuit breaker, there are advantages of mini-mized number of breaks,lower number of parts, simple structure,high reliability and long period of inspection.

LW25-252/T4000-50 circuit breaker with spring operating mechanism was developed and fnished testing in Sep. 2006.
LW25D-126 (145)/T3150-40 (31.5) single-phase operated circuit breaker with spring operating mechanism was developed and fnished testing in Dec. 2006.
LW25A-252/Y4000-50 three-phase mechanically circuit breaker with hydraulic operating mechanism was develped and fnished testing in Jan. 2007.

LW25-126/T4000-40 special circuit breaker for reactive compensation fnished appraisal with swithing back-to-back capacitor bank current of 1600A, switching reactor in series current of 1600A, breaking single capacitor
bank current of 3500-4000A, whinch can meet the requirement of general switchgear and branch switchgear for reactive compensation in UHV.
220kV and above circuit breakers with "XD" brand awarded "China awarded Brand" in Sept . 2007.

2.Normal Service Conditions
2.1 Altitude:≤1000m
2.2 Average relative humidity monthly:≤90%
2.3 Max.wind:≤35m/s
2.4 Pollution class: Third, Class: Fourth class
2.5 Ambient temperature :-35ºC~40ºC
(It's satisfed under the condition of -40ºC in heavy cold area)
2.6 Max.temperature difference daily:25K
2.7 Earthquake intensity:8 degree
2.8 Max.iced thickness:10mm
2.9 Max. radiance from sun:1000W/m2
Note: When product is used under the condition out of above range,
user and manufacturer shall consult to confrm.
Product Parameters
No Ltem Unit LW9-40.5/T LW9-72.5/T  LW9A-72.5/T LW25-126T/145T  LW25D-126T/145T   LW25-252T LW25A-252/Y LW15B-252/Y LW15-252/Q LW-252/Y
1 Rated Voltage KV 40.5 72.5 126/145 252 252 252
2 Rated Frequency Hz 50 50 50 50 50 50
3 Rated Normal Current A 3150/4000 3150/4000 2000.  3150.  4000 4000 3150.   4000 4000.    5000
4 Rated Short-Circuit Breaking Current KA 50 31.5/40 31.5/40 40.     50 50 63
5 Rated Short-Circuit Making Current KA 125 80/100 80/100 100.    125 125 160
6 Rated Short-Time Withstand Currend And Duration KA 50(3s) 31.5/(4s)/40(4s) 315/(4s)/40(4s) 40/(4s)/50(4s) 50(4s) 63(3s)
7 Rated Peak Whithsand Current KA 125 80/100 80/100 100.    125 125 160
8 Short-Line fault breaking Current KA le×90% le×75%  
9 Rated Out-Of-Phase BreakingCurrent KA le×25%  
10 Creepage Distance cm/KV 3.1 3.1 2.5.  3.1 2.5.   3.1 2.5.   3.1
11 1Min Power Frequency Withstand Voltage Dry Test Across Open Breaks  To Earth KV 95+23.4       95 160+42           160 230+95              275 460+145                                  460                                   520+165/520         460
  Wet Tese Across Open Breaks  To Earth KV 95               95 160+42           160 230+95                275 460+145                               460  460+145     460
12 Rated lightning Impulse Whithstand Voltage   Across Open Breaks  To Earth KV 185+33      185 350+59           350 650+100            650 1050+200                           1050 1188+226/1188         1188
13 5Min.Power FrequenceyWithstand Voltage Under Zero -Gauge pressure KV 1.3×40.5×3 1.3×72.5×√3 1.3×145×√3 1.3×252×√3 1.3×252×√3
14 Closing Time ms 150 ≤150 ≤150 ≤110 ≤110 55-80
15 Opening Time ms ≤30 ≤30 ≤30 ≤30 ≤25 14-30
16 Breaking   Time ms ≤60 ≤60 ≤60 ≤60 ≤50 ≤50
17 Close-Open  Time ms 40-60 40-60 40-60 50-70 40-60 40-60
18 Operating    Asynchronism      Between  poles Open ms 2 ≤2 ≤2 ≤30 ≤3 ≤3
Close ms ≤4
19 Rated Reclose Operating Sequence   O-0.3s-CO-180s-CO
20 Rated Pressure Of  SF6 Gas Mpa 0.5 0.50 ;0.40 0.5;0.40 0.60; 0.40 0.6 0.60 
21 Alarm/Lock Pressure Of  SF6 Gas Mpa 0.45/0.40 0.45/0.40; 0.35/0.3 0.45/0.40; 0.35/0.30 0.55/0.50;0.35/0.33 0.55/0.50 0.55/0.50
22 Annual Leakage Of SF6  Gas % ≤0.5
23 Number Of Breaks Per Pole Piece 1
24 Opening Time Of  Mechanisem Times 10000
25 Load On teminal In Y-Direction N 750 750 1250 1500 1500 1500
26 Load On teminal In X-Direction N 500 500 750 1000 1000 1000
27 Load On teminal In Z-Direction N 750 750 1000 1250 1250 1250
28 Resistance Of Man Circuit   ≤50 ≤50 ≤45 ≤45 ≤42 ≤42
29 Operating  Mechanism   Spring mechanism Spring mechanism Spring mechanism Spring Mechanism Or Hydraulic Mechanism Hydraulic Mechanism OrPneumatic Mechanism Hydraulic Mechanism
30 Weight Of SF6  Gas Filled For Each CB kg 6 4 6 30 30 30
31 Weight Of One Set Of CB kg 1100 1100 1400/2100 3500 4000/4500 3700
32 Applied Standards GB/T1984,     IEC62271-100,    DL/T402
Detailed Photos
High Voltage Porcelain Type SF6 Gas Circuit Breaker LW9-40.5 LW9-72.5 LW9A-72.5
High Voltage Porcelain Type SF6 Gas Circuit Breaker LW9-40.5 LW9-72.5 LW9A-72.5
High Voltage Porcelain Type SF6 Gas Circuit Breaker LW9-40.5 LW9-72.5 LW9A-72.5
High Voltage Porcelain Type SF6 Gas Circuit Breaker LW9-40.5 LW9-72.5 LW9A-72.5
High Voltage Porcelain Type SF6 Gas Circuit Breaker LW9-40.5 LW9-72.5 LW9A-72.5
High Voltage Porcelain Type SF6 Gas Circuit Breaker LW9-40.5 LW9-72.5 LW9A-72.5


 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now