Notice:
Rated operational current: 160A 250A 400A 630A 800A 1000A 1250A 1600A.
Number of poles: single-pole, two-pole, three-pole...n-pole
Control voltage: DC: 110V, 220V.
AC: 220V, 380V.
For Example: EVS160/3-220VAC means rated operational current 160a, control voltage 220VAC for three-pole type vacuum contactor.
Product Description
Main Application
EVS160-630/EVS800-1600 serial vacuum contactor is applicable to the power system with 50/60HZ alternating current, rated operating voltage up to 1140V(2000V), rated operating current up to 1600A to switch-on or off the circuit at a long-distance, to start frequently and control alternating motor under and to form electromagnetic starter with other kinds of protective device. EVS800-1600 is applicable to AC-1, AC-2, FUNCTION CLASS.
Because vacuum contactor has more advantages than the traditional air AC contactor for its longer lifetime, higher reliability, and the auxiliary switches that can combine electrical device, therefore, it can completely take the place of the traditional air AC contactor. Its economical characteristic can be displayed better in the application for the field of mine, metallurgical, chemical and petrolic industry, and heavy industries department.
Product Parameters
Model |
EVS160 |
EVS250 |
EVS400 |
EVS630 |
EVS800 |
EVS1000 |
EVS1250 |
EVS1600 |
Rated operating Current(A) |
160 |
250 |
400 |
630 |
800 |
1000 |
1250 |
1600 |
Rated operating voltage(AC)(V) |
1140 |
1140 |
1140 |
1140 |
1140 (2000) |
1140 (2000) |
1140 (2000) |
1140 (2000) |
Rated operational frequency(HZ) |
50-60 |
50-60 |
50-60 |
50-60 |
50-60 |
50-60 |
50-60 |
50-60 |
Rated turn-on capacity(A) |
1920 |
3000 |
4800 |
7560 |
3200 |
4000 |
5000 |
6400 |
Ratedturn-offcapacity(A) |
1600 |
2500 |
4000 |
6300 |
3200 |
4000 |
5000 |
6400 |
The max. Allowable power of the motor at 660V (KW) |
140 |
220 |
350 |
560 |
|
|
|
|
Mechanical Lifetime (time) |
≥1×106 |
Electrical Lifetime (time) |
AC2 |
5×106 |
5×106 |
5×106 |
3×106 |
0.5×106 |
0.5×106 |
0.5×106 |
|
AC4 |
1.2×105 |
1.2×105 |
0.8×105 |
1.2×105 |
|
|
|
|
Max. Mechanical operating frequency (Time/h) |
3000 |
3000 |
2000 |
2000 |
2000 |
2000 |
2000 |
|
- Technical data for auxiliary circuits
Rated operating voltage(V) |
Rated thermal current(A) |
Service life (time) |
Usage mode |
Rated operating current A |
mechanics |
electrics |
AC |
DC |
DC220 |
6 |
≥5×106 |
≥2×105 |
DC14 |
|
0.4A |
AC380 |
6 |
AC14 |
4A |
|
- Power consume of the drive mechanism and the closing & releasing time of the vacuum contactor
Power consume of the drive mechanism |
Closing & releasing time of the contactor |
Rated Current (A) |
Number of pole |
Power consume |
Closing Time (ms)≤ |
Releasing time |
start |
keep |
AC(ms) ≤ |
DC(ms) ≤ |
AC(VA) |
DC(W) |
AC(VA) |
DC(W) |
160 |
1 |
250 |
250 |
24 |
24 |
30 |
40 |
30 |
2 |
500 |
500 |
48 |
48 |
3 |
750 |
750 |
72 |
72 |
250 |
1 |
250 |
250 |
24 |
24 |
30 |
40 |
30 |
2 |
500 |
500 |
48 |
48 |
3 |
750 |
750 |
72 |
72 |
400 |
1 |
300 |
300 |
60 |
60 |
30 |
40 |
15 |
2 |
600 |
600 |
60 |
60 |
3 |
900 |
900 |
90 |
90 |
630 |
1 |
300 |
300 |
60 |
60 |
30 |
40 |
15 |
2 |
600 |
600 |
60 |
60 |
3 |
900 |
900 |
90 |
90 |
800 |
1 |
300 |
300 |
60 |
60 |
40 |
30 |
25 |
2 |
600 |
600 |
60 |
60 |
3 |
900 |
900 |
90 |
90 |
1000 |
1 |
300 |
300 |
60 |
60 |
40 |
30 |
25 |
2 |
600 |
600 |
60 |
60 |
3 |
900 |
900 |
90 |
90 |
1250 |
1 |
300 |
300 |
60 |
60 |
40 |
30 |
25 |
2 |
600 |
600 |
60 |
60 |
3 |
900 |
900 |
90 |
90 |
1600 |
1 |
300 |
300 |
60 |
60 |
40 |
30 |
25 |
2 |
600 |
600 |
60 |
60 |
3 |
900 |
900 |
90 |
90 |