LVB series of A.C. oil-insulated inverted current transformer

Product Details
Type: Current Transformer
Phase: Single
Operation Condition: Outdoor
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (11)
  • LVB series of A.C. oil-insulated inverted current transformer
  • LVB series of A.C. oil-insulated inverted current transformer
  • LVB series of A.C. oil-insulated inverted current transformer
  • LVB series of A.C. oil-insulated inverted current transformer
  • LVB series of A.C. oil-insulated inverted current transformer
  • LVB series of A.C. oil-insulated inverted current transformer
Find Similar Products
  • Overview
  • General Introduction
  • Product Description
  • Detailed Photos
Overview

Basic Info.

Model NO.
LVB
Usage
Measurement
Winding Form
Single Layer & Tightly Wound Type
Insulating Medium
Insulating Oil
Installation
Strut Type
Magnetic Circuit Structure
Combined Type
Voltage Transformation Principle
Electromagnetic Type
Operation ambient temperature
-40 to +45 centigrade
Altitude
not exceed 3000m
Icing thickness
10mm
Pollution Grade
3 or 4
Site
indoor or outdoor
Transport Package
Wooden
Specification
from 35KV to 550KV
Trademark
XD
Origin
China
HS Code
8504311000
Production Capacity
200000

Product Description

General Introduction

LB series of outdoor A.C. oil-insulated current transformer (CT) is suitable for power system of rated system voltage from 35kV to 220KV, which is mainly used for measuring curent, power and energy metering, simultaneously to the relay protection device and automatic control device provide current signal.
Structure: Full sealed structure with capacitance-graded oil impregnated paper and Metal Expander
Location: indoor or outdoor
Ambient temperature:-40 to +45 centigrade (Freezing field can meet -45 centigrade)
Wind load: not exceed 35 m/s
Altitude: not exceed 3000m
Icing thickness: not exceed 10mm
Seismic strength: 8
Pollution Grade : 3 or 4
Note: If the service conditions beyonds thc above provisions, pleasc contact us and we can solve as quick as possible.

Product Description
Transformer model LB-220W2 LBT-220W2 (W3) LB-132W2 LB-110GYW2 LB-110W2 (W3) LBR-110W2 (W3) LB-123W2 LB-66W3 LB-35W2
Highest system voltage (KV) 252 252 145 126 126 126 126 126 40.5
Rated frequency (Hz) 50 50 50 50 50 50 50 50 50
Power freguency withstand voltage (KV) 460 460 275 230 230 230 230 160 95
BIL, 1.2/50μs full ware (KV) 1050 1050 650 550 550 550 550 350 185
Choppcd test (KV) 1208 1208 748 633 633 633 633 403 213
Flashover distance (mm) ≥2150 2150 1440 1440 1220 1220 1220 1220 350
Creepage distance (mm) ≥6300 (7812) ≥6300 (7812) ≥3150 ≥3150 ≥3150(3906) ≥3150(3906) ≥3150(3906) ≥1813(2248) ≥1015
Rated primary current (A) 2500 2500 2500 2500 2500 2500 2500 2500 2000
Rated secondary current (A) 1;5 1;5 1;5 1;5 1;5 1;5 1;5 1;5 1;5
Accuracy class (Upon request) 0.2S; 0.5; 5P; 10P 0.2S; 0.5; 5P; 10P; TPY 0.2S; 0.5; 5P; 10P 0.2S; 0.5; 5P; 10P 0.2S; 0.5; 5P; 10P 0.2S; 0.5; 5P; 10P 0.2S; 0.5; 5P; 10P 0.2S; 0.5; 5P; 10P 0.2S; 0.5; 5P; 10P
Rated  output (VA) 10-60 10-60 10-50 10-50 10-50 10-50 10-50 10-50 10-40
Instrument security factor (FS) 5;10 5;10 5;10 5;10 5;10 5;10 5;10 5;10 5;10
Rated accuracy limit factor 25 25;30;40 20 20 20 20 20 20 20
Rated short-time current/3s (max) Ith (KA) 50 50 40 40 40 40 40 40 42
Rated dynamic current (max) Idyn (KA) 125 125 100 100 100 100 100 100 105
Dimensions (mm) 900×780×3770 915×570×4123 774×600×2734 774×600×2734 714×560×2420 594×485×2550 594×485×2550 714×560×2420 440×440×1800
Mounting size (mm) 700×460 710×460 475×475 475×475 475×475 310×360 310×360 475×475 265×265
Net weight (Kg) 1310 1700 760 760 590 450 450 590 165
Gross weight (Kg) 1586 1930 880 880 670 530 530 670 200
LVB series of A.C. oil-insulated inverted current transformer
Transformcr model LVBT-500W2 LVBT-330W2 LVBT-220W3 LVB-220W3 LVB-110W3 LVB-66W3
Highest system voltage (KV) 550 363 252 252 126 72.5
Rated frequency (Hz) 50 50 50 50 50 50
Power frequency withsland voltage (KV) 680 510 460 460 230 160
BIL, 1.2/50μs full ware (KV) 1175 950 / / / /
Choppcd test (KV) 1550 1175 1050 1050 550 350
Flashover distance (mm) 3930 2675 2195 2200 1200 1200
Creepage distance (mm) ≥13750 ≥11253 ≥7812 ≥7812 ≥3906 ≥2248
Rated primary current (A) 4000 4000 4000 4000 3000 3000
Rated secondary current (A) 5;1 5;1 5;1 5;1 5;1 5;1
Accuracy class (Upon request) 0.1; 0.2S; 0.5; 5P; 10P; TPY 0.1; 0.2S; 0.5; 5P; 10P; TPY 0.1; 0.2S; 0.5; 5P; 10P; TPY 0.2S; 0.5; 5P; 10P 0.2S; 0.5; 5P; 10P 0.2S; 0.5; 5P; 10P
Rated  output (VA) 10-50 10-50 10-50 10-50 10-50 10-50
Instrument security factor FS 5;10 5;10 5;10 5;10 5;10 5;10
Rated accuracy limit factor 30 30 30 30 30 30
Rated Short-time current/3s (max) Ith (KA) 63 63 63 63 50 50
Rated dynamic current (max) Idyn (KA) 160 160 160 160 125 125
Dimension (mm) 1000×1200×6200 745×1127×4265 745×1060×3745 604×980×3650 535(604)  ×780(930) ×2230(2370) 535(604)  ×780(930) ×2230(2370)
Mounting size (mm) 650×650 600×600 600×600 600×600 450×450 450×450
Net weight (Kg) 2250 1000 800 500 480 480
Gross weight (Kg) 3100 1350 1070 790 550 550
Detailed Photos
LVB series of A.C. oil-insulated inverted current transformer
LVB series of A.C. oil-insulated inverted current transformer
LVB series of A.C. oil-insulated inverted current transformer
LVB series of A.C. oil-insulated inverted current transformer
LVB series of A.C. oil-insulated inverted current transformer
LVB series of A.C. oil-insulated inverted current transformer
LVB series of A.C. oil-insulated inverted current transformer
LVB series of A.C. oil-insulated inverted current transformer
LVB series of A.C. oil-insulated inverted current transformer

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier