• Outdoor HV AC Dead Tank SF6 Gas Circuit Breaker
  • Outdoor HV AC Dead Tank SF6 Gas Circuit Breaker
  • Outdoor HV AC Dead Tank SF6 Gas Circuit Breaker
  • Outdoor HV AC Dead Tank SF6 Gas Circuit Breaker
  • Outdoor HV AC Dead Tank SF6 Gas Circuit Breaker
  • Outdoor HV AC Dead Tank SF6 Gas Circuit Breaker

Outdoor HV AC Dead Tank SF6 Gas Circuit Breaker

Type: Circuit Breaker
Structure: Dead Tank
Installation: Vertical
Application: Substation
Size: Large
Operation Voltage: High Voltage
Gold Member Since 2024

Suppliers with verified business licenses

Gansu, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (11)
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
Overview

Basic Info.

Model NO.
LW24
Shape
Strainght
Material
Sf6 Gas
Certification
ISO9001, CCC
Brand
Xd
Phase
3
Outdoor or Indoor
Outdoor
Rated Voltage
40.5kv to 252kv
Rated Current
2000A, 3150A
Transport Package
Non-Fumigation Wooden Box
Specification
Please refer to the attachment
Trademark
XD
Origin
China
HS Code
8535291000
Production Capacity
5000

Product Description

Outdoor High Voltage Porcelain Type SF6 Gas Power Circuit Breaker for Substation.
Product Description
1.General
Type LW24- /T outdoor H.V. A.C. dead tank SF6 gas circuit breaker is a new kind of circuit breaker with self-blast interrupter and spring operating mechanism, developed by Xi'an XD High Voltage Apparatus Co.,Ltd. (former Xi'an High Voltage Apparatus Works), on the basis of technology of product imported from Mitsubishi, Japan.The latest achieve-arc extinguishing principle of gas-blast pressure adapting with breaking-current is employed,by which most of energy required for breaking rated short-circuit current are acquired from arc itself.Therefore, the demand for operating power is reduced signifcantly. The three pole interrupters are placed inside three metal enclosures respectively.
The circuit breaker can be mechanically three-phase gang-operated. Both remote electrical control and local manual control can be real- ized. Type CT20-II spring operating mechanism, provided with the product, is a kind of mechanism with low operating power, minimum maintenance work needed and high reliability. The product reaches international advanced level in the respect of main technical performance.
 
2.Normal Service Conditions
2.1.Altitude: ≤3000m
2.2.Humidity monthly: ≤90%
2.3.Max .wind velocity: ≤35m/s
2.4.Pollution class: IV class
2.5.Ambient air temperature: -35ºC~40ºC(It's satisfed under condition of -40ºC in heavy cold area)
2.6.Max .temperature difference daily: 25K
2.7.Earthquake withstand density: 9 degree
2.8.Ice coating: ≤10mm
2.9.Max. radiance from sun: 1000 W/m2
Note: When product is used under the condition out of above range, user and manufacturer shall consult to confrm.
Product Parameters
No Item Unit LW24-40.5 LW24-72.5 LW24-125T  LW24-145T LW24-252/T
1 Rated Voltage kV 40.5 72.5 126 145 252
2 Rated Normal Current A 3150 4000
3 Rated Frequency Hz 50
4 Rated Short Circuit Breaking Current kV 40 40 40 31.5 50
5 Rated Short-Time Withstand Currend And Duration kV 40 (4s) 40 (4s) 40 (3s) 31.5 (3s) 50 (3s)
6 Rated Peak Whithsand Current kV 100 100 100 80 125
7 Rated Making Current (Peak) kV 100 100 100 80 125
8 Rated Short Time Power Frequency Withstand Voltage(Rms)            
Between Breaks kV 95+23.4 160+42 315 460+145
To Earth kV 95 160 275 460
9 Rated Lightning Impulse Withstand Voltage            
Between Breaks kV 185+33 350+59 650+100 1050+200
To Earth kV 185 350 650 1050
10 Creepage Distance mm/kv 31 31 25,   31
11 Breaking Time ms ≤60 ≤60 ≤60
12 Opening Time ms ≤30 ≤30 ≤30
13 Closing Time ms ≤100 ≤100 ≤100
14 Mechanical Endurance Tim 1000 ≤5000
15 Rated Operation Sequence            
16 Rated Pressure Of  SF6 Gas (at20ºC) MPa 0.50,  0.40 0.5 0.60 
17 Alarm/Lock Pressure Of SF6 Gas MPa 0.45,  0.40;    0.35/0.30 0.45/0.40 0.55/0.50
18 Rated Voltage Of Control Circuit V DC220/110
19 Rated Voltage Of Energy-Store Motor Circuit V DC220/110,      AC220  
20 Breaking Number Of Rated Short-Circuit Breaking Current Time 20
21 Rated Back-To-Back Capacitor Back Breaking Current A 1500 2000      
22 Rated Shunt Reactor Switching Current A 1600 1500      
 
CT Datasheet
NO Transformation Ratio Accuracy Output Capacity
1 100-2000 0.5 class 10VA-50VA
2 200-2000 0.2 class 5VA-50VA
3 100-2000 10P10 10VA-50VA
4 200-2000 10P15 10VA-50VA
5 200-2000 10P20 5VA-50VA
 
 
Detailed Photos
Outdoor HV AC Dead Tank SF6 Gas Circuit Breaker
Outdoor HV AC Dead Tank SF6 Gas Circuit Breaker
Outdoor HV AC Dead Tank SF6 Gas Circuit Breaker
Outdoor HV AC Dead Tank SF6 Gas Circuit Breaker
Outdoor HV AC Dead Tank SF6 Gas Circuit Breaker
Outdoor HV AC Dead Tank SF6 Gas Circuit Breaker


 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now